With the expansion of the range of using 5.5mm medical endoscope camera module price, doctors in various departments use 5.5mm medical endoscope camera module price more and more frequently. 5.5mm medical endoscope camera module price is a delicate medical device, but as long as it can be used and maintained correctly, damage can be avoided.

1. After using the 5.5mm medical endoscope camera module price, it should be washed clean and the water stains should be dried. If there are stains on the front of the lens, it should be wiped gently with lens paper, cotton swab or fine gauze.

2. The 5.5mm medical endoscope camera module price shall be kept in a special counter and placed in a special packing box lined with soft sponge or polyurethane foam.

3. All 5.5mm medical endoscope camera module prices and surgical instruments shall be stacked neatly, and shall not be placed in an overlapping manner. After the box cover is covered, the internal endoscope and instruments shall not collide with each other during handling.

4. When taking out or putting in the 5.5mm medical endoscope camera module price, hold both hands flat and handle gently. As the endoscope tube is very thin, it will be bent and deformed when it is squeezed, bumped, bent, or dropped, resulting in damage to the lens or optical axis offset, resulting in unclear images or unusable images. Therefore, when taking out or putting in the 5.5mm medical endoscope camera module price from the packaging box, gently take out or put in the tube with both hands flat, and do not lift a section to pull it out.

5. When the 5.5mm medical endoscope camera module price is moved in a hard container such as a tray, it should be placed separately from other instruments to avoid excessive turbulence and collision with the camera.

6. The packing box shall be provided with desiccant to keep the box dry.

7. Some 5.5mm medical endoscope camera module prices are not resistant to high temperature and high pressure. This is mainly because the epoxy resin glue used for the mirror end packaging will open under high temperature and pressure, causing water to enter the mirror tube. After the optical system enters the water, the vision will be blurred. Therefore, this kind of endoscope cannot be used in high temperature and high pressure methods such as boiling and high pressure steam * *.