SPECIFICATION OF BLUETOOTH PULSE OXIMETER
Product Color | Grey/Orange |
Display | OLED |
Working Voltage | D.C.2.2V~D.C.3.4V |
Temperature | 5ºC~40ºC |
Relative humidity | 15%~80% |
Air pressure | 860hpa~1060hpa |
Size | 58(H)*34(W)*30(D)mm |
SpO2:
Measurement range: 35~100%
Accuracy: ±2% (80%~100%); ±3%(70%~79%)
Pulse Rate:
Measurement range: 25~250bpm
Accuracy: ±2bpm
Resolution: 1bpm
Product Features Of Bluetooth Pulse Oximeter
► Portable and Convenient .
► One-touch operation .
► Lower consumption .
► Low voltage reminder .
► Bluetooth BLE .
► Free charge APP .
► Support communication protocol .
► CE0123 FDA 510 ANVISA ISO13485 INMETRO
The portable bluetooth electronic finger oximeter can detect the blood oxygen saturation and pulse of people through the finger, and can upload the data system to form a database, record the value of each blood oxygen parameter, and provide users with analysis, evaluation, early warning and feedback functions.
The finger pulse oximeter with bluetooth is a common electronic oximeter implanted with a bluetooth chip, and the wireless transmission function of bluetooth is used to realize the wireless transmission of measurement data.
Scope And Population Of Bluetooth Finger Pulse Oximeter
1: People with vascular disease
2: Seniors over 60 years old
3: The environment with insufficient oxygen intake and insufficient oxygen supply.
Suitable for oxygen bar, community medical treatment, family, sports health care (used before and after exercise, not recommended during exercise), outdoor activities.
Intended Use Of a Bluetooth Finger Pulse Oximeter
1: This product is intended for monitoring blood oxygen saturation (spo2), pulse rate (PR) and pulse strength.
2: The oximeter monitors these physiological signals of the patient by using the blood oxygen probe, and further processes them, and then displays the numerical results on the LCD screen.
3: Evaluation of test results: From medical analysis, the oxygen content in the blood is greater than or equal to 95, which is a normal index: between 60-100 pulses per minute, it is a normal index.
4: If the values you have detected do not meet the above two indicators, please test 2-3 times at different time points, and keep continuous testing for 2-3 days. If the values still do not meet the standards, it is recommended that you go to the hospital for details disease.
Pulse oximeter bluetooth exporter Berry specializes in supplying all kinds of medical electronic equipment. We are committed to the research and development, manufacturing and sales of medical electronic instruments in the field of monitoring.